4000W Edge bander
The edge-banding laser system independently developed and produced by Hosting Laser is a semiconductor direct-coupled output laser with fixed rectangular spot output and continuously adjustable beam width. It is easy to install and debug, and the expected service life can reach 100,000 hours. The use effect of constant value and maintenance-free can really solve the worries of the core laser system in the edge banding process of furniture manufacturers.
Inquiry Now

Laser parameters


Optical Parameters
Project Output Power(w)3000w4000w
Power Instability<3%
Power Adjustment Range/%10~100
Center Avelength(nm)980
Fiber Output Head TypeQBH
Output Fiber Length5m
Electrical Properties
Operating VoltageThree-phase four-wire AC 380v±10%
Control MethodRS-232
Maximum Power Consumption(w)80009000
Other Features
Dimensions/mm834.5*610*249830*670*260
Cooling MethodWater Cooling
Working Environment Temperature range-15-35℃


Laser scanning head parameters


Product Parameters
scan range/mm18-25(Continuously adjustable)35-50(Continuously adjustable)
Dimensions/mm100*46*315120*80*320
Focal length range/mmstandard value 280
Working environment temperature range-15-35℃


Edge thickness


HS3000HS4000
15-25mm30-45mm


Daily maintenance regulations for laser edge banding system


(1)Check whether the red light indicator spot is abnormal before the equipment is used every day. If there are abnormal black spots, conduct a surface inspection of the laser exit window.

(2)The surface inspection of the laser exit window must be carried out when the equipment is powered off, and the routine inspection frequency is once a week. If contamination is found, replace the included lenses.

(3)Check whether the water level and temperature of the water cooler have reached the set temperature before equipment work every day. Preheating and precooling are required in winter and summer, usually 15 minutes.

(4)The cooling water of the water cooler needs to be deionized and purified water, and the cooling water containing impurities will damage the optical part. The standard water cooler setting water temperature is 25°.

(5)Laser equipment operators must be trained to operate as required. They must wear laser protective glasses during work and are prohibited from visually viewing laser beams and reflected and scattered beams.

(6)It is prohibited to insert any objects into the laser light path. Including metal, lenses, wood pieces, paper pieces, hands, etc.

(7)It is prohibited to disassemble and bend the optical fiber, and it is prohibited to hang objects on the optical fiber.

(8)For long-time shutdown, the output window needs to be protected. The cooling water needs to be drained.

(9)The standard operating temperature of laser equipment is 15-35°.

(10)When the winter temperature is lower than 0°, plan 1: Use a professional brand of antifreeze, recommended: Clariant industrial grade antifreeze (type: AntifrogenN, ethylene glycol-water type, industrial supplies, poisonous to humans. ) The use volume accounts for 10%-20% of the water tank volume, and cannot exceed 20%. Note: Propylene glycol-water type is prohibited!

Scheme 2: (applicable to the case where the laser does not need to run continuously)

Just keep the chiller running at night, no need to power up the laser. Make sure the coolant is circulating and the temperature is not below freezing.

(11) In humid weather in summer, in order to prevent condensation, the temperature of the water cooler can be set to 28-30° to avoid condensation.